Section B: Physical Inclusion
APPROACH: Transportation
Public
Comments/additional information about transportation:
Bus stop less than one mile from the agency.
APPROACH: ParkingPallas Fitness Lot 1
Number of designated accessible spaces:
(If unlined, approximate number of accessible spaces)
2 spaces
Width of designated accessible spaces:
99 inches
Number of designated accessible spaces with access aisles:
2 spaces
Width of access aisles:
99 inches
Distance from parking to entrance:
(If no designated accessible parking, measure distance from middle of parking lot/area to entrance)
58 feet
Describe the surface of the route of travel:
Cement Sidewalk
Slope of route of travel (at its steepest incline):
7 %
Width of route of travel (at its narrowest point):
66 inches
Comments/additional information about parking and route of travel to entrance:
Van Accessible
ENTER: EntrancesMain Entrance
Manual
If yes, distance between doors:
180 inches
Clear open width of door:
35 inches
Opening force of door:
(enter 0 pounds if automatic door)
12 pounds
Pull
Push pull
Clear space on pull (handle) side of door:
36 inches
Comments/additional information about entrance:
There is also access through a large garage door in the front of the building if needed. During warmer weather, this door is typically open.
USE: Registration/Reception/Check-in Area
Describe the surface of the route of travel:
Concrete/Rubber Floor
Slope of route of travel (at its steepest incline):
0 %
Width of route of travel (at its narrowest point):
48 inches
Height of counter:
31 inches
Comments/additional information about reception/registration/check-in area:
The registration area is often not staffed. When all participants are registering for the first time, they should contact a staff person to assist with this process. After a person is registered, they no longer need to check in to access the facility.
USE: Public Restroom/ToiletMale Restroom
Describe the surface of the route of travel:
Rubber Floor
Slope of route of travel (at its steepest incline):
0 %
Width of route of travel (at its narrowest point):
35 inches
Clear open width of door to restroom:
35 inches
Opening force of door:
(enter 0 pounds if automatic door)
6 pounds
Push plate
Pull
Wall
Sink
Wall
USE: Elevator(s)N/A
Slope of route of travel (at its steepest incline):
0 %
USE: StairsN/A
Slope of route of travel (at its steepest incline):
0 %
Notes about physical inclusion