Section B: Physical Inclusion
APPROACH: Transportation
Public
APPROACH: ParkingAgency Parking (By Pool)
Number of designated accessible spaces:
(If unlined, approximate number of accessible spaces)
0 spaces
Distance from parking to entrance:
(If no designated accessible parking, measure distance from middle of parking lot/area to entrance)
74 feet
Describe the surface of the route of travel:
Pavement
Slope of route of travel (at its steepest incline):
23 %
Width of route of travel (at its narrowest point):
119 inches
APPROACH: ParkingAgency Parking (By Baseball Fields)
Slope of route of travel (at its steepest incline):
0 %
ENTER: EntrancesLou Bova Recreation Center
Step count
14 stairs
Handrail type
Metal
If yes, width of ramp (at its narrowest point):
56 inches
If yes, slope of ramp (at its steepest incline):
23 %
If yes, depth of ramp landing:
58 inches
If yes, describe the surface of ramp:
Concrete
Describe the type of railing on the ramp:
n/a
Manual
If yes, distance between doors:
109 inches
Clear open width of door:
40 inches
Opening force of door:
(enter 0 pounds if automatic door)
10 pounds
Entry
Push pull
Clear space on pull (handle) side of door:
24 inches
USE: Registration/Reception/Check-in Area
Describe the surface of the route of travel:
Tile
Slope of route of travel (at its steepest incline):
0 %
Width of route of travel (at its narrowest point):
39 inches
Height of counter:
29 1/2 inches
USE: Public Restroom/ToiletWomen
Describe the surface of the route of travel:
Tile
Slope of route of travel (at its steepest incline):
0 %
Width of route of travel (at its narrowest point):
33 1/2 inches
Clear open width of door to restroom:
33 1/2 inches
Opening force of door:
(enter 0 pounds if automatic door)
13 pounds
Push plate
Push plate
Clear space on pull (handle) side of door:
22 inches
If no, provide dimensions of free floor space in stall/toilet area:
42 inches x 40 inches
Toilet seat height:
18 inches
Height of sink:
32 inches
Wall
Depth of knee space under sink:
(from outer edge of sink to pipes or other obstruction under sink)
26 1/2 inches
Sink
Wall
If wall-mounted, height of hand dryers/paper towel dispensers:
57 inches
USE: Elevator(s)
Slope of route of travel (at its steepest incline):
0 %
None
USE: Stairs
Describe the surface of the route of travel:
Concrete
Slope of route of travel (at its steepest incline):
36 %
Width of route of travel (at its narrowest point):
61 inches
Step count
14 stairs
Notes about physical inclusion
No content available