Section B: Physical Inclusion

APPROACH: Transportation

Yes
Public
Yes
Comments/additional information about transportation:
Call 758-3383 to arrange accessible bus through First Transit (www.odyssey.net/subscribers/corttrans). Mulitple cab services also serve the area.

APPROACH: ParkingYWCA of Cortland

(If both are present, assess the agency parking)

Agency
Lined
Yes

(International symbol of accessibility or clear wording)

Yes
Number of designated accessible spaces:

(If unlined, approximate number of accessible spaces)

2 spaces
Width of designated accessible spaces:
116 inches
Number of designated accessible spaces with access aisles:
2 spaces
Width of access aisles:
126 inches
Distance from parking to entrance:

(If no designated accessible parking, measure distance from middle of parking lot/area to entrance)

184 feet
Yes
Yes
Describe the surface of the route of travel:
pavement
Slope of route of travel (at its steepest incline):
0 %
Width of route of travel (at its narrowest point):
64 inches
Comments/additional information about parking and route of travel to entrance:
Designated space is located in the back of building. The back doors are not automatic doors but do lead to an elevator. Accessible entrance is located in the front of building.

ENTER: EntrancesFront/Main Entrance

No
Yes
Step count
4 stairs
Handrail type
metal pipe on both sides of stairs
Yes
If yes, width of ramp (at its narrowest point):
42 1/2 inches
If yes, slope of ramp (at its steepest incline):
15 %
If yes, depth of ramp landing:
60 inches
If yes, describe the surface of ramp:
pavement
Describe the type of railing on the ramp:
metal pipe
Manual
Automatic
Yes
If yes, distance between doors:
66 inches
Clear open width of door:
34 inches
Opening force of door:

(enter 0 pounds if automatic door)

5 pounds
Pull
Push pull
Clear space on pull (handle) side of door:
24 inches
Comments/additional information about entrance:
Automatic doors do not work. The doors are left open or do not lock completely during hours of service.

USE: Registration/Reception/Check-in AreaAgency Registration

Yes
Yes
Describe the surface of the route of travel:
Tile/Rug
Slope of route of travel (at its steepest incline):
0 %
Width of route of travel (at its narrowest point):
36 inches
Yes
Height of counter:
34 inches
N/A
Yes
If no, provide dimensions of free space in registration area:
60 inches x 60 inches

(word, picture, and Braille or raised lettering)

No

USE: Public Restroom/ToiletWomen's Locker Room

Yes
Yes
Describe the surface of the route of travel:
Tile to rubberized flooring
Slope of route of travel (at its steepest incline):
0 %
Width of route of travel (at its narrowest point):
36 inches

(e.g. family, companion, single room)

Yes
Family

(word, picture, and Braille or raised lettering provided for signs)

Yes
Yes
Clear open width of door to restroom:
33 inches
Opening force of door:

(enter 0 pounds if automatic door)

5 pounds
Push pull
Entry
Clear space on pull (handle) side of door:
25 inches
N/A

(60" circle)

Yes
Yes
Yes
Number of grab bars:
3 bars
Toilet seat height:
16 inches
Yes
Height of sink:
30 inches
Wall
Depth of knee space under sink:

(from outer edge of sink to pipes or other obstruction under sink)

19 inches
Yes
Wall
If wall-mounted, height of soap dispensers:
36 inches
Wall
If wall-mounted, height of hand dryers/paper towel dispensers:
36 inches
Comments/additional information about public restroom/toilet:
Agency plan to add unisex accessible bathroom to 1st floor. The locker room bathrooms are inclusive and recommended to people with wheelchairs.

USE: Public Restroom/Toiletrestroom near pool

N/A
Describe the surface of the route of travel:
not assessed

(e.g. family, companion, single room)

Yes

(word, picture, and Braille or raised lettering provided for signs)

Yes
Yes
Clear open width of door to restroom:
33 1/2 inches
Opening force of door:

(enter 0 pounds if automatic door)

5 pounds
Lever
Lever
Clear space on pull (handle) side of door:
18 inches
Yes

(60" circle)

Yes
If no, provide dimensions of free floor space in stall/toilet area:
61 inches x 65 inches
Yes
Number of grab bars:
2 bars
Toilet seat height:
18 1/2 inches
N/A
Height of sink:
36 inches
Depth of knee space under sink:

(from outer edge of sink to pipes or other obstruction under sink)

8 inches
If wall-mounted, height of soap dispensers:
45 inches
If wall-mounted, height of hand dryers/paper towel dispensers:
40 inches

USE: Public Restroom/Toiletschool age program

N/A
Describe the surface of the route of travel:
not assessed

(e.g. family, companion, single room)

No

(word, picture, and Braille or raised lettering provided for signs)

No
Yes
Clear open width of door to restroom:
29 inches
Opening force of door:

(enter 0 pounds if automatic door)

1 pounds
Knob
Knob
Clear space on pull (handle) side of door:
3 inches
Yes

(60" circle)

No
No
Toilet seat height:
16 inches
N/A
Height of sink:
31 inches
Depth of knee space under sink:

(from outer edge of sink to pipes or other obstruction under sink)

9 1/2 inches
If wall-mounted, height of soap dispensers:
39 inches
If wall-mounted, height of hand dryers/paper towel dispensers:
51 inches

USE: Public Restroom/Toilet2nd floor locker room

N/A
Describe the surface of the route of travel:
not assessed

(e.g. family, companion, single room)

No

(word, picture, and Braille or raised lettering provided for signs)

Yes
Yes
Clear open width of door to restroom:
33 1/2 inches
Opening force of door:

(enter 0 pounds if automatic door)

12 pounds
Knob
Knob
Clear space on pull (handle) side of door:
18 inches
Yes

(60" circle)

No
If no, provide dimensions of free floor space in stall/toilet area:
39 inches x 37 1/2 inches
Yes
Number of grab bars:
2 bars
Toilet seat height:
16 inches
N/A
Height of sink:
31 1/2 inches
Depth of knee space under sink:

(from outer edge of sink to pipes or other obstruction under sink)

9 1/2 inches
If wall-mounted, height of soap dispensers:
49 inches
If wall-mounted, height of hand dryers/paper towel dispensers:
40 inches

USE: Elevator(s)Front Elevator

Yes
Yes
Yes
Describe the surface of the route of travel:
carpet
Slope of route of travel (at its steepest incline):
0 %
Width of route of travel (at its narrowest point):
36 inches
Elevator control panel height:
36 inches
Audible
Tactile
Visual
Elevator door width:
36 inches
Yes
Size (clear space) of elevator car:
68 inches x 51 1/2 inches
Yes
Comments/additional information about the elevator:
Elevator doors remain open for ten seconds.

USE: StairsMain Stairs

Yes
Yes
Describe the surface of the route of travel:
Tile
Slope of route of travel (at its steepest incline):
0 %
Width of route of travel (at its narrowest point):
36 inches
Step count
22 stairs
Yes
Yes
Yes
Comments/additional information about stairs:
There are double handrails lining the right side of the staircase. The lower hand rail is for younger children.

Notes about physical inclusion

No content available