Section B: Physical Inclusion
APPROACH: Transportation
APPROACH: ParkingDwyer Park
Number of designated accessible spaces:
(If unlined, approximate number of accessible spaces)
3 spaces
Width of designated accessible spaces:
101 inches
Number of designated accessible spaces with access aisles:
3 spaces
Width of access aisles:
96 inches
Distance from parking to entrance:
(If no designated accessible parking, measure distance from middle of parking lot/area to entrance)
65 feet
Describe the surface of the route of travel:
concrete
Slope of route of travel (at its steepest incline):
12 %
Width of route of travel (at its narrowest point):
45 1/2 inches
ENTER: EntrancesPavilion Main Entrance
Step count
4 stairs
Handrail type
steel
If yes, width of ramp (at its narrowest point):
36 inches
If yes, slope of ramp (at its steepest incline):
5 %
If yes, depth of ramp landing:
60 inches
If yes, describe the surface of ramp:
concrete
Describe the type of railing on the ramp:
wooden
Manual
Clear open width of door:
32 inches
Opening force of door:
(enter 0 pounds if automatic door)
9 pounds
Pull
Push/Pull Paddle/Bar
Push/Pull Paddle/Bar
Lever
Clear space on pull (handle) side of door:
18 inches
USE: Public Restroom/ToiletMain Building Unisex Restoom
Describe the surface of the route of travel:
concrete
Clear open width of door to restroom:
38 1/2 inches
Opening force of door:
(enter 0 pounds if automatic door)
6 pounds
Lever
Lever
Clear space on pull (handle) side of door:
18 inches
If no, provide dimensions of free floor space in stall/toilet area:
60 inches x 60 inches
Toilet seat height:
16 inches
If no, provide dimensions of free space in sink area:
60 inches x 60 inches
Height of sink:
32 1/2 inches
Wall
Depth of knee space under sink:
(from outer edge of sink to pipes or other obstruction under sink)
8 inches
Wall
If wall-mounted, height of soap dispensers:
42 1/2 inches
Wall
If wall-mounted, height of hand dryers/paper towel dispensers:
39 inches
Notes about physical inclusion
No content available